  1. Changes in the 2024 International Building Code (IBC)

    Oct 16, 2009 · The 2024 IBC® contains many important changes such as: Duties and powers of the building official: an overall reformat of Section 104 regulating duties of the building official, the …

  2. Egress Capacity Calculator - 2024 IBC

    Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020.3, and Section 1010.1.1 for doors.

  3. Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and ...

    Oct 16, 2009 · Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted. It outlines the scope, purpose, and administrative …

  4. Group E Occupancies Explained - IBC 305 (2024) - The Building Code …

    Oct 16, 2009 · Do you agree with the following interpretation and summary of this important section? Definition and Scope of Group E Occupancies: Group E occupancy primarily involves buildings or …

  5. Changes in Sound Transmission IBC 2024 Section 1207

    Oct 16, 2009 · SECTION 1207.1 This section shall apply to common interior walls, partitions and floor/ceiling assemblies between adjacent dwelling units and sleeping units or between dwelling units …

  6. 2018 IBC Section 1020 Corridors - The Building Code Forum

    Apr 20, 2015 · I had commented earlier on a different but similar question, but my situation is different so I am posting a new thread. Table 1020.1 has minimum fore resistance of corridors. I had a code …

  7. 1006.2.1 Egress based on occupant load and common path of egress …

    Dec 23, 2020 · 2021 IBC Section 1006.2.1 requires that two exit or exit access doorways shall be provided to any space if the design occupant load or the common path of egress travel exceeds the …

  8. 2018 IBC Required Ramp Width (1012.5.3, 1014.8) - The Building Code …

    Jan 10, 2024 · I am reviewing the requirements for required width of ramps in the 2018 IBC and am having trouble reconciling 1012.5.3 and 1014.8, am hoping someone can help clarify this for me. 1. …

  9. S-1, Self-Storage Facility: Fire wall/Sprinkler

    Jan 7, 2015 · The requirement was relocated to Section 903.2.9.4 in the 2021 IBC with an exception for self-storage facilities under certain conditions. Also, the requirement was changed to a "fire area" …

  10. Changes to Load Combinations in Section 1605 of the 2021 IBC

    Oct 16, 2009 · By removing the transcription of the ASCE 7 Load Combinations from the IBC, in addition to avoiding duplication of nearly identical material, we expect to reduce the likelihood that design …